Insertion type

flow-captor 4114.xx (flow switch for water based media up to 30 bar / ø 1 ¼" / 32 mm / stainless steel)

flow switch for water based media up to 30 bar / ø¼" /

32 mm in a rugged stainless steel version (full encapsulation)

 

4114.03 (24 V DC)

4114.70 (24 V AC/DC)

 

Operating principle: calorimetric
Measuring range: 0.2 m/s - 2 m/s, continuously adjustable

 

Further versions: housing stainless steel AISI 316,

cooling version up to 100 °C / 212 °F medium temperature (S101), extended length (S110/xx)

 

 

Download:

Data sheet 4114.03

Data sheet 4114.70

4114.03

flow-captor 4120.1x (flow switch for water based media / transistor output)                 best seller

flow switch for water based media

Operating principle: calorimetric
Measuring range: 0 - 20 cm/s to 0 - 300 cm/s,

continuously adjustable

Protection class: IP65
Operating voltage: 18 - 30 VDC

Options: different sensor head sizes and lengths, different

materials, BSP and NPT, cooling version up to 130 °C (S101) 

 

Also available for oil based media.

 



Download:

Data sheet 412x.1x

User manual 412x.1x

Application example

4120.13

flow-captor 4120.1xM (flow switch for water based media / stainless steel / M12-plug / transistor output)

flow switch for water based media in a rugged stainless steel version / full encapsulation (transistor output)


Operating principle: calorimetric

Electrical output: transistor output
Operating voltage: 18 - 30 VDC, 10.5 - 36 VDC or 19 - 72 VDC
Measuring range: 0-20 cm/s up to 0-300 cm/s,

continuously adjustable
Protection class: IP67 
Options: different sensor head sizes and lengths, different

materials, BSP and NPT, cooling version up to 130 °C (4120.1xMK)​​​​
 

Also available for oil based media. 

 

 

Downloads:

Data sheet 412x.1xM 18-30 VDC

Data sheet 412x.1xM 10.5-36 VDC

Data sheet 412x.1xM 19-72 VDC

User manual 412x.1xM

Application example

4120.13M

flow-captor 4120.1x Tri-Clamp® (flow switch for water based media in the food industry / compact unit)

flow-switch for water based media in the food industry
 

4120.13A S113/xx S110/xx - sensor head for TRI-CLAMP® system

4120.13A S114/xx S110/xx - high temperature version

sensor head for TRI-CLAMP® system


EHEDG-certified (click for more information)


Operating principle: calorimetric

Measuring range: from 0 - 20 cm/s to 0 - 300 cm/s,

continuously adjustable
Pressure: up to 100 bar
Medium temperature:

-20 °C up to +80 °C / 176 °F (S113)

-20 °C up to +130 °C / 266 °F (S114)
Diameter of the lid: 50.5 or 64.0 mm
Sensor head length: 47.5 or 67.0 mm
Operating voltage: 18 - 30 V DC

 

Also available for oil based media.

 

 

Download:

Data sheet 4120.1xA S113/xx S110/xx

Data sheet 4120.1xMA S113/xx S110/xx

Data sheet 4120.1xA S114/xx S110/xx

 4120_1xA S114_xx S110_xx frei_Loony_Gelb_cmyk4x3 

flow-captor 4120.4xM (flow switch for water based media / stainless steel / relay or optocoupler output)

flow switch for water based media in a rugged stainless steel housing (full encapsulation) 

Electrical output:
4120.40/.41M   relay output
4120.42/.43M   optocoupler output

Operating principle: calorimetric

Operating voltage: 18 - 30 VDC
Protection class: IP67
Measuring range: 0 - 20 cm/s up to 0 - 300 cm/s,

continuously adjustable

Further versions:
4120.40/.41M S140 (Brad-Harrison-plug)
4120.40/.41M S141 (Binder-plug)
4120.40/.41M S150 (relay for 250 VDC / 280 mA)

4220.40/.41M (with additional analogue temperature output)

 

Also available for oil based media.

 

 

Download:

Data sheet 412x.40M/.41M

Data sheet 412x.40M/.41M S140

Data sheet 412x.40M/.41M S141

Data sheet 412x.42M/43M

Data sheet 422x.40M/.41M

Data sheet 422x.40M/41M S141

User manual 412x.40M/.41M

412x.4xM

flow-captor 4120.5xM (flow switch for water based media / stainless steel / solid state relay output)

flow switch for water based media in a rugged stainless steel version (full encapsulation) with solid state relay output (SSR)

Operating principle: calorimetic

Electrical output: solid state relay output
Operating voltage: 90 - 250 VAC/DC
Protection class: IP67
Measuring range: 0 - 20 cm/s up to 0 - 300 cm/s, 

continuously adjustable

Further versions:
4120.5xM S141 (4-pin Binder male socket)
4120.5xMA S110/xx (different sensor head lengths)

4220.5xM (with additional analogue temperature output)

 

Also available for oil based media. 

 

 

Download:

Data sheet 412x.5xM

Data sheet 412x.5xM S141

Data sheet 422x.5xM

User manual 412x.5xM

412x.5xM

flow-captor 4120.8xM (flow switch for water based media / stainless steel / relay output VAC/DC)

flow switch for water based media in a rugged stainless steel version (full encapsulation) with relay output VAC/DC

Operating principle: calorimetic

Electrical output: relay output
Operating voltage: 90 - 250 VAC/DC
Protection class: IP67
Measuring range: 0 - 20 cm/s up to 0 - 300 cm/s,

continuously adjustable

Further versions:
4120.8xM S140 (Brad-Harrison-plug)
4120.8xM S141 (Binder-plug)

4120.8xM S142 (UV-protected cable)
4120.8xMK (cooling version up to 130 °C)

4220.8xM (with additional analogue temperature output)

 

Also available for oil based media.

 

 

Download:

Data sheet 412x8xM

Data sheet 412x.8xM S140

Data sheet 412x.8xM S141

Data sheet 412x.8xMK S140

Data sheet 422x.8xM S141

User manual 412x.8xM

4120.81M

flow-captor 4140.13 (flow switch for water based media / factory-set switching point)

flow-switch for water-based media with factory-set

switching point

 

Lower cost alternative to the flow-captor 4120.13.

LED display for power and switching status.

 

Operating principle: calorimetric
Setpoint: factory-set 30 cm/s, 80 cm/s or 120 cm/s

(must be specified when ordering)
Operating voltage: 18 - 30 VDC
Electrical output: PNP n. o. (closer) currentless
Protection class: IP 65

 

 

Download:

Data sheet 4140.13

User manual 4140.13

4140.13

flow-captor 4220.1xM (flow switch for water based media / stainless steel / transistor output / additional analog temperature output)

flow switch for water based media in a rugged stainless steel version / full encapsulation / analog temperature output


Operating principle: calorimetric

Electrical output: transistor output

Temperature output: analog 4 - 20 mA
Operating voltage: 18 - 30 VDC
Measuring range: 0-20 cm/s up to 0-300 cm/s,

continuously adjustable
Protection class: IP67 

 

Also available for oil based media. 

 

 

Downloads:

Data sheet 422x.1xM

4220.13M

flow-captor 4220.4xM (flow switch for water based media / stainless steel / relay output / additional analog temperature output)

flow switch for water based media in a rugged stainless steel housing (full encapsulation), relay output and additional analog temperature output

 

Operating principle: calorimetric

Operating voltage: 18 - 30 VDC
Protection class: IP67
Measuring range: 0 - 20 cm/s up to 0 - 300 cm/s,

continuously adjustable

Further versions:
4220.40/.41M S140 (Brad-Harrison-plug)
4220.40/.41M S141 (Binder-plug)

 

Also available for oil based media.

 

 

Download:

Data sheet 422x.4xM

User manual 422x.xx

4220.41M S141

flow-captor 4220.8xM (flow switch for water based media / stainless steel / relay output VAC/DC / additional analog temperature output)

flow switch for water based media in a rugged stainless steel version (full encapsulation) with relay output VAC/DC

and additional analog temperature output

Operating principle: calorimetic

Electrical output: relay output VAD/DC
Operating voltage: 90 - 125 VAC/DC
Protection class: IP67
Measuring range: 0 - 20 cm/s up to 0 - 300 cm/s,

continuously adjustable

Further versions:
4220.8xM S140 (Brad-Harrison-plug)
4220.8xM S141 (Binder-plug)

4220.8xM S142 (UV-protected cable)
4220.8xMK (cooling version up to 130 °C)

 

Also available for oil based media.

 

 

Download:

Data sheet 422x.8xM S141

User manual 422x.xx

4220.81M S141

flow-captor 4220.xxF/.xxT xx °C (flow switch for water based media with simultaneous monitoring of flow and temperature)

flow switch for water based media with simultaneous

monitoring of flow and temperature
 

Operating principle: calorimetric
Measuring range: 0 - 20 cm/s to 0 - 300 cm/s,

continuously adjustable
Medium temperature: -20 °C to +80 °C / -4 °F to +176 °F
Set-point temperature: 

50 °C, 70 °C, 80 °C / 122 °F, 158 °F, 176 °C, factory set

(other set-points on request)
Operating voltage: 18 - 30 VDC

 

 

Download:

Data sheet 4220.1xF/1xT xx °C

User manual 4220.1xF/1xT xx°C

4220.13F/.12T

flow-captor 4220.xxF/.xxTM xx °C (flow switch for water based media with simultaneous monitoring of flow and temperature / stainless steel housing)

flow switch for water based media in a rugged stainless steel housing (full encapsulation) with simultaneous monitoring of flow and temperature 

 

Operating principle: calorimetric
Measuring range: 0 - 20 cm/s to 0 - 300 cm/s,

continuously adjustable
Medium temperature: -20 °C to +80 °C / -4 °F to +176 °F
Set-point temperature: 

50 °C, 70 °C, 80 °C / 122 °F, 158 °F, 176 °F, factory set

(other set-points on request)
Operating voltage: 18 - 30 VDC

 

 

Download:

Data sheet 4220.1xF/1xTM xx °C

User manual 4220.1xF/1xT xx°C

4220.xxF/xxTM xx °C

flow-captor 4120 S100 + 4020.1x S100 (flow switch for water based media / high temperature / remote system)

flow switch for water based media, high temperature type

(remote system)

Medium temperature: up to max. 140 °C / 284 °F (S100)
Operating principle: calorimetric
Measuring range: 0 - 20 cm/s up to 0 - 300 cm/s,

continuously adjustable
Operating voltage: 18 - 30 VDC

 

Further versions: different sensor head sizes and lengths (S110/xx), different materials, BSP and NPT

 

Also available for oil based media.

 

 

Download:

Data sheet 4120 S100 + 402x.13 S100

4120 S100 + 4020.1x S100

flow-captor 4120 S103 + 4020.1x S103 (flow switch for water based media in the food industry / remote system)

flow switch for water based solutions in the food industry

(remote system)
 

for TRI-CLAMP® system


EHEDG-certified (click for more information)


Operating principle: calorimetric
Measuring range: 0-20 cm/s to 0-300 cm/s,

continuously adjustable
Medium temperature: up to 135 °C / up to 275 °F
Operating voltage: 18 - 30 VDC

 

 

Download:

Data sheet 4120 S103 + 4020.1x S103

 4120 S103 + 4020.1x S103 

flow-captor 4220 S102 + 4020.46 (flow switch for water based media with simultaneous temperature monitoring / remote system)

flow switch for water based media with simultaneous

temperature monitoring (remote system)

Measuring principle: calorimetric
Measuring range: 0-20 cm/s bis 0-300 cm/s,

continuously adjustable

Medium temperature: -10 °C bis +90 °C
Operating voltage: 18 - 30 VDC

 



Download:

Data sheet 4220 S102 + 4020.46

4220 S102 + 4020.46